Allied Engineering - Super Hot Boilers
  • Facebook
  • Google
  • Home
  • Corporate
    • About Us
    • Careers
  • Product Lineup
    • HSE High-Efficiency Condensing Boiler
    • AAA Commercial Gas Boiler
    • AAE Commercial Gas Boiler
    • MG Mini-Gas Boiler
    • SSC Space Saver Combo
    • SG Saturn Series Boiler
    • MSE Mini-Star Electric Boiler
    • EPP Indirect Fired Water Heater
    • Electric Booster Water Heater
    • CX Copper Coil Water Heater
    • Discontinued Products
      • GSE Boiler
      • SC Sealed Combustion
      • BT Electric Boiler
      • E Electric Boiler
      • TC Electric Boiler
      • C Coil
    • Product Service Bulletins
  • Resources
    • News & Events
    • Boiler Rebates Programs
    • Product Service Bulletins
    • Commercial Specification Submittal Form
  • Contact
    • Contact
    • Contact Form
    • Newsletter Signup
    • Warranty Registration
Home» Product Lineup » Electric Booster Water Heater

Electric Booster Water Heater





The Economical Choice for Electric Boosters

  • Features
  • Technical
  • Literature
  • Service Bulletins

INNER TANK CONSTRUCTION

Standard horizontal booster inner tanks are constructed of stainless steel. Will not rust – 10 year warranty.

ELEMENTS

Heating elements are 1″ I.P.S., utilizing copper sheathing on the hairpin rods to provide the ultimate in corrosion resistance, long life and efficient operation. All models specifying 480V to 600V are equipped with four bolt flange mounted heating elements utilizing copper sheathing on the hairpin rods and stainless steel flange to provide the ultimate in corrosion resistance and long life.

JACKET AND INSULATION

An attractive rectangular jacket with backed enamel finish, stainless steel front panel. Two inches of fiber glass insulation surrounds the inner tank. Sturdy legs are standard or stainless steel hanging supports for under counter suspension are available. (Specify when ordering.)

CONTROLS

A custom designed rapid response thermostat with adjusting dial, switches a magnetic contactor which completes the power circuit to the heating elements except on 4B and 5B models which are controlled by a thermostat. This electrical system is prewired on the right hand side of each booster away from high ambient temperatures. A neon pilot light, mounted on the front, is wired to indicate that there is power to the heater and to show when the booster is operating. Prewired electrical control panel mounted on the booster complete with magnetic contactors, internal adjusting thermostat and pilot light.

PLUMBING INSTALLATION

Locate booster as close to dishwasher as possible. Must be connected with copper tubing.
Insure that incoming water is 140°F to pressure reducing valve furnished preset for 20 PSI.
It is mandatory that a diatrol expansion chamber and shock absorber be installed in the line between booster and dishwasher. (as close to dishwasher as possible)
Install relief valve (furnished) on heater and plumb discharge in accordance with local codes.
Install pressure temperature gauge in a tee on inlet between reducing valve and booster.
Unions should be used in connecting the piping to the booster.
It is recommended that the inlet and outlet lines be insulated to prevent heat loss.
Check flow pressure with water flowing through the booster and, if necessary, readjust the pressure reducing valve to 20 PSI or to pressure recommended by dishwasher manufacturer.

ELECTRICAL INSTALLATION

Ensure booster is full of water before turning on electricity. Elements will burn out immediately without water.
Check booster data plate for correct amperage voltage and phase, and size supply wiring accordingly.
Supply wires must be suitable to 75°C.
A fused disconnect switch of at least 125% of the booster amperage rating must be installed between the power supply and the booster.
Insure that plumber has installed booster with access to the elements and control panel.
Set thermostat to give desired water temperature at dishwasher (usually 180°F).
Lift relief valve handle to be sure booster is completely filled with water.
The pilot light indicates when power is on, and the booster is operating.

Specifications

 

Electric Booster for DishwasherElectric Booster Water Heater for Dishwashers

 

Hanging brackets are supplied if specified with the order

 

 

 

Super Hot Electric Booster Heater Specifications (Flange Type Elements)

BOOSTER MODEL NUMBERS,
kW RATINGS AND MAX. AMPERAGE DRAW
Model
Number
kW Btu/Hr TankCapacity
U.S. Gal
U.S. Gal./Hr
40ºF
Rise
Maximum Amperage Draw Approx.
Shipping
Weight
Single Phase Three Phase
208 240 208 240 480 600
304B 4 13,649 4.27 41 19.2 16.7 - - - - 60 LBS
305B 5 17.062 4.27 52 24.0 20.8 - - - - 60 LBS
306B 6 20,474 4.27 62 28.8 25.0 16.6 14.4 7.2 5.8 60 LBS
307B 7 23,884 4.27 72 33.7 29.2 21.0* 18.2* 9.1* 7.3* 60 LBS
309B 9 30,711 4.27 93 43.3 37.5 25.0 21.6 10.8 8.7 60 LBS
312B 12 40,948 4.27 124 57.7 50.0 33.3 28.8 14.4 11.5 65 LBS
313B 13 44,356 4.27 135 62.5 54.2 37.6* 32.6* 16.3* 13.0* 65 LBS
315B 15 51,185 4.27 156 72.1 62.5 46.4* 40.2* 20.1* 16.1* 65 LBS
318B 18 61,422 4.27 187 86.5 75.0 54.6* 47.3* 23.7* 18.9* 70 LBS
424B 24 81,895 5.80 249 115 100 66.5 57.7 28.8 23.1 70 LBS
427B 27 92,124 5.80 280 130 113 74.9 64.9 32.4 26.0 70 LBS
430B 30 102,369 5.80 311 144 125 83.2 72.1 36.0 28.8 75 LBS
436B 36 122,843 5.80 373 173 150 100 86.5 43.3 34.6 75 LBS
439B 39 133,068 5.80 405 188 163 108 93.7 48.8* 39.1* 80 LBS
545B 45 153,554 5.80 467 216 188 125 108 54.1 43.3 90 LBS
554B 54 184,264 5.80 560 260 225 150 130 64.9 51.9 90 LBS
SPECIFY MODEL NUMBER, VOLTAGE AND EITHER
1 OR 3 PHASE WHEN ORDERING
* Delta connection (unbalanced load) amperage of high leg indicated.

Booster Heater Cross Reference Chart

All sizing are based on dishwasher manufacturer ratings. Confirm the booster size with dishwasher manufacturer before ordering it. Allied Engineering Company is not responsible for incorrect sizing of applications.

DISHWASHERS BOOSTER
HEATER CROSS REFERENCE CHART
40ºF
RISE
70ºF
RISE
ADAMATION CSL-1390, CA-2, CA-3,
CA-4
439B (2) 436B
CA, CA-1 554B (2) 545B
BLAKESLEE UC-21 306B 312B
D-8 309B 313B
Series “R” & “F”-CC,
-EE, -LL, -MM, -LLL, -MMM, -PCC, -PEE,
    -PLL, -PMM (Multi-tank) with
suffix “LC”
313B 424B
Series XF-LL, XF-PLL,
XF-MM, XF-PMM, XF-EEE, XF-LLL, XF-MMM
    (Multi-tank) with suffix “LC”
317B 430B
DD-8 318B 430B
Series R-L, R-PL,
R-M, R-PM, F-L, F-PL, F-M, F-PM (single-tank)
436B 554B
Series XF-L, XF-PL,
XF-M, XF-PM (single tank)
(2) 436B —
Series XF-PEE, XF-PLL,
XF-PMM, XF-EEE, XF-LLL, XF-MMM (Multi-tank)
545B (2) 430B
FA (Flight-A-Round)
and RA (Rack-A-Round) use comparable “F” listing.
– –
CHAMPION UH1 306B 309B
DH1, DH1C 309B 318B
44WS, 66WS 315B 427B
PP28 427B 545B
40KB, 44KB, 54KB,
60KB, 64KB
436B 554B
UC-C 545B (2) 436B
UC-CW (6 ft center
max)
554B (2) 439B
CHEMICAL METHODS ASSOC. CMA-44H with tank
heater
424B 545B
HOBART LX-30 304B 307B
LX-18C, XL-30C, LX-40C,
UM-4D, UMP-4D, WM-1D, WMP-1D, WM-5
304B 307B
LX-18 305B 309B
WM-5C 306B 309B
SM-6T2 306B 312B
WM-5 307B 312B
AM-14T, AM-14F, AM-14TC 309B 313B
UM-4, UMP-4, WM-1,
WMP-1
309B 315B
AM-12, AM-12C, AM-14,
AM-14C
309B 312B
C-44AW, CRS-66AW,
CPW-80AW
312B 424B
C-64W, CRS-86W, CPW-100W,
C-88W, CRS-110W, CPW-124W
424B 436B
FT800W 424B 439B
C-64A, CRS-86A, CPW-100A,
CMT-44
430B 554B
C-44, CRS-66, CPW-80,
C-44A, CRS-66A, CPW-80A, C-88A, CRS-110A, CPW-124A
436B 554B
C-64, CRS-86, CPW-100 545B (2) 436B
FT-600, FT-700, C-54,
CRS-76, CPW-90
554B (2) 439B
FT-300 554B (2) 545B
FT800 439B 554B
FT800S, CRS-76A, CPW-90A,
C-54A
439B (2) 436B
UTW-28, UTW-28C 318B 436B
INSINGER Commander 18-3, 18-4,
18-4h, Ensign 40-2
306B 312B
Trac 321, Trac 321-2/RPW 318B 430B
Admiral 44-4, 66-4 424B 436B
Acmiral 44, 66-3 424B 439B
Speeder 7, 64, 86-3,
Century 14
424B 545B
Master (all) 436B 554B
Clipper (all) 424B 545B
R106-2, Super 106-2 427B 545B
Defender 436B 554B
JACKSON JP-24, JP-24B, JP-24F,
JP-24BF
304B 306B
24B Series — 304B
10AB, 10APRB — 305B
44CE*, 66 CERPW 430B 554B
54CE, 76 CERPW 436B (2) 430B
64CE, 86 CERPW 427B 439B
100 312B 424B
100B, 100PRB, 150B,
150PRB
— 309B
150 312B 318B
200 307B 312B
200B — 306B
Tempstar, Tempstar
SDS
306B 312B
AJ-44, AJ-66, AJ-80 424B 545B
AJ-54, AJ-76, AJ-90 436B (2) 430B
AJ-64, AJ-86, AJ-100 424B 439B
*Model #44CE w/SN1999
or below requires larger booster than listed.
  – -
KNIGHT EQUIPMENT (CANADA) LTD. KLE-112-HL 307B 312B
METALWASH/
INTEDGE
FW4 312B 318B
STERO SF-1RA, SC20-1 307B 312B
SF-2RA, SF-2DRA, SD-2RA,
SDRA, SDRA-PACK
312B 318B
SCT-44, SCT-44-10,
SCT-54, SCT-76S, SCT-76SC, SCT-76SM
436B 554B
SCT-64,
SCT-76, SCT-80, SCT-94, SCT-108, SCT-120, SCT-94S,
SCT-108S, SCT-120S, SCT-94SC, SCT-108SC, SCT-120SC, SCT-94SM, SCT-120SM,
SCT-150SM
545B 554B
U-31-A 436B 554B
U-31-A2,
STPCW-5, STPCW-19, STPCW-19PS, STPCW-20, STPCW-22, STPCW-24
545B (2) 436B
STPCW-12PS, STPC-15S 554B (2) 554B
STPC-12PS, STPC-15S 554B (2) 439B
STPC-15, STPC-19,
STPC-19S, STPC-20, STPC-22, STPC-24
436B (2) 430B
STBUW-14 554B (2) 554B
SC-2-4, SC-6-4, SC-1-2-3,
SC-1-6-4, SC-5-6-4, SC-5-2-4
436B 545B
SC-2-3-4,
SC-6-3-4, SC-2-7-4, SC-1-2-7-4, SC-1-6-3-4, SC-5-2-3-4,
SC-1-6-7-4, SC-5-6-3-4, SC-5-2-7-4
430B (2) 427B
SC20-2 312B 424B
SC-2-8,
SC-2-9, SC-1-2-8, SC-5-6-8, SC-6-8, SC-6-9, SC-1-6-8, SC-5-6-9, SC-5-2-9,
SC-1-6-9, SC-5-2-8
318B 436B
VULCAN-HART R16BTF, CU16BTF 309B 318B
3D20TF, CD20TF 312B 424B
A-64 Series, A-81
Series
430B 554B
A44 Series, A54 Series,
CP-2, CP-3, HP-3
545B (2) 439B

Literature

  • Electric_Booster_Installation_&_Service_Manual.pdf

Service Bulletins

Warranty Cards

Remember that warranties are only valid if a warranty card is filled out and returned to Allied Engineering by the home owner. Online registration is available at our Product Registration Section of the website.

© 2012 Allied Engineering Company
  • Terms of Use
  • Privacy Policy
  • Sitemap
  • Contact