THE NEW AAA COMMERCIAL BOILER
– 85% Thermal Efficiency
– 2012 DOE & NRCAN Compliant
– Commercial, Industrial, Institutional
– Natural Gas or Propane
– 480 to 3,000 MBH Input
– Heat exchanger built according to ASME
– No gaskets or push nipples
With 22 sizes from 480 to 3,000 MBH, there is a Super Hot AAA for any commercial, industrial and institutional application. This latest generation of our commercial boilers is 2012-DOE and NRCAN compliant. The AAA series features improved efficiency through increased heat exchanger fin area, an optimized burner, and improved insulation.
Specifications
SPECIFICATIONS AND DIMENSIONS | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MODEL NUMBER | INPUT * | OUTPUT * | DIM A ** | DIM B | DIM C | DIM D | |||||||
MBH | kW | MBH | kW | H.P. | in | cm | in | cm | in | cm | in | cm | |
AAA-480 | 480 | 141 | 408 | 120 | 12.2 | 24 | 61 | 16.5 | 41.9 | 10 | 25.4 | 74 | 188 |
AAA-600 | 600 | 176 | 510 | 149 | 15.2 | 27 | 68.6 | 16.5 | 41.9 | 10 | 25.4 | 74 | 188 |
AAA-720 | 720 | 211 | 612 | 179 | 18.3 | 30 | 76.2 | 11.5 | 29.2 | 12 | 30.5 | 71.7 | 182.1 |
AAA-840 | 840 | 246 | 714 | 209 | 21.3 | 33 | 83.8 | 11.5 | 29.2 | 14 | 35.6 | 73.9 | 187.7 |
AAA-960 | 960 | 281 | 816 | 239 | 24.4 | 36 | 91.4 | 11.5 | 29.2 | 14 | 35.6 | 73.9 | 187.7 |
AAA-1080 | 1080 | 317 | 918 | 269 | 27.4 | 39 | 99 | 11.5 | 29.2 | 16 | 40.6 | 77 | 195.6 |
AAA-1200 | 1200 | 352 | 1020 | 299 | 30.5 | 42 | 106.7 | 11.5 | 29.2 | 16 | 40.6 | 77 | 195.6 |
AAA-1320 | 1320 | 387 | 1122 | 329 | 33.5 | 45 | 114.3 | 13 | 33 | 18 | 45.7 | 79.8 | 202.7 |
AAA-1440 | 1440 | 422 | 1224 | 359 | 36.6 | 48 | 121.9 | 13 | 33 | 18 | 45.7 | 79.8 | 202.7 |
AAA-1560 | 1560 | 457 | 1326 | 389 | 39.6 | 51 | 129.5 | 13 | 33 | 18 | 45.7 | 79.8 | 202.7 |
AAA-1680 | 1680 | 492 | 1428 | 419 | 42.7 | 54 | 137.2 | 11.5 | 29.2 | 20 | 50.8 | 79.7 | 202.4 |
AAA-1800 | 1800 | 528 | 1530 | 448 | 45.7 | 57 | 144.8 | 11.5 | 29.2 | 22 | 55.9 | 81.7 | 207.5 |
AAA-1920 | 1920 | 563 | 1632 | 478 | 48.8 | 60 | 152.4 | 11.5 | 29.2 | 22 | 55.9 | 81.7 | 207.5 |
AAA-2040 | 2040 | 598 | 1734 | 508 | 51.8 | 63 | 160 | 11.5 | 29.2 | 24 | 61 | 83.6 | 212.3 |
AAA-2160 | 2160 | 634 | 1836 | 538 | 54.9 | 66 | 167.6 | 11.5 | 29.2 | 24 | 61 | 83.6 | 212.3 |
AAA-2280 | 2280 | 669 | 1938 | 568 | 57.9 | 69 | 175.2 | 11.5 | 29.2 | 24 | 61 | 83.6 | 212.3 |
AAA-2400 | 2400 | 703 | 2040 | 598 | 61 | 72 | 182.9 | 11.5 | 29.2 | 24 | 61 | 83.6 | 212.3 |
AAA-2495 | 2495 | 731 | 2121 | 622 | 63.4 | 75 | 190.5 | 13 | 33 | 2×18 | 2×45.7 | 79.8 | 202.7 |
AAA-2640 | 2640 | 774 | 2244 | 658 | 67.1 | 78 | 198.1 | 13 | 33 | 2×18 | 2×45.7 | 79.8 | 202.7 |
AAA-2760 | 2760 | 809 | 2346 | 688 | 70.1 | 81 | 205.7 | 13 | 33 | 2×18 | 2×45.7 | 79.8 | 202.7 |
AAA-2880 | 2880 | 845 | 2448 | 717 | 73.2 | 84 | 213.4 | 13 | 33 | 2×18 | 2×45.7 | 79.8 | 202.7 |
AAA-3000 | 3000 | 880 | 2550 | 747 | 76.2 | 87 | 221 | 13 | 33 | 2×18 | 2×45.7 | 79.8 | 202.7 |
SPECIFICATIONS AND DIMENSIONS CONTINUED | |||||||
---|---|---|---|---|---|---|---|
MODEL NUMBER | DIM E *** | GAS CONN F †† | WATER CONTENT | SHIPPING WEIGHT | |||
in | cm | NPT | US GAL | L | lb | Kg | |
AAA-480 | 12 | 30.5 | 1” | 5.56 | 21 | 675 | 307 |
AAA-600 | 13.5 | 34.3 | 1” | 6.75 | 25.5 | 725 | 330 |
AAA-720 | 15 | 38.1 | 1” | 7.95 | 30.1 | 790 | 359 |
AAA-840 | 16.5 | 41.9 | 1” | 9.14 | 34.6 | 860 | 391 |
AAA-960 | 18 | 45.7 | 1 1/4” | 10.34 | 39.1 | 940 | 427 |
AAA-1080 | 19.5 | 49.5 | 1 1/4” | 11.53 | 43.6 | 990 | 450 |
AAA-1200 | 21 | 53.3 | 1 1/4” | 12.73 | 48.2 | 1050 | 477 |
AAA-1320 | 22.5 | 57.2 | 1 1/4” | 13.92 | 52.7 | 1140 | 518 |
AAA-1440 | 24 | 61 | 1 1/4” | 15.12 | 57.2 | 1205 | 548 |
AAA-1560 | 25.5 | 64.8 | 1 1/4” | 16.31 | 61.7 | 1270 | 577 |
AAA-1680 | 27 | 68.6 | 1 1/2” | 17.51 | 66.3 | 1350 | 614 |
AAA-1800 | 28.5 | 72.4 | 1 1/2” | 18.7 | 70.8 | 1440 | 655 |
AAA-1920 | 30 | 76.2 | 1 1/2” | 19.9 | 75.3 | 1520 | 691 |
AAA-2040 | 31.5 | 80 | 1 1/2” | 21.09 | 79.8 | 1605 | 730 |
AAA-2160 | 33 | 83.8 | 1 1/2” | 22.28 | 84.3 | 1645 | 748 |
AAA-2280 | 34.5 | 87.6 | 1 1/2” | 23.48 | 88.9 | 1690 | 768 |
AAA-2400 | 36 | 91.4 | 1 1/2” | 24.67 | 93.4 | 1770 | 805 |
AAA-2495 | 2×18.25 | 2×46.4 | 2” | 25.87 | 97.9 | 1850 | 841 |
AAA-2640 | 2×19.75 | 2×50.20 | 2” | 27.06 | 102.4 | 1890 | 859 |
AAA-2760 | 2×20.25 | 2×51.4 | 2” | 28.26 | 107 | 1935 | 880 |
AAA-2880 | 2×21.00 | 2×53.3 | 2” | 29.45 | 111.5 | 1975 | 898 |
AAA-3000 | 2×21.75 | 2×55.3 | 2” | 30.65 | 116 | 2020 | 918 |
* For Propane models, derate Input and Ouput by 10%
* In Canada: For altitudes above 2,000 feet, contact the factory for the appropriate Input derate.
* In U.S.A.: For altitudes above 2,000 feet, reduce input 4% for each 1000 feet above sea level.
** Add 3” to dimension ‘A’ (1 1/2” to each side of boiler) to allow for 3” NPT water connections.
*** AAA2495 and above use two draft hoods and Dimension “E” is measured from both left and right hand sides.
† AAA480 and AAA600 are supplied with DIM B = 16.5” but can be field modified to DIM B = 10.5”
†† Gas Connection “F” shows typical sizes only. Connections may vary depending on the gas valve used.
Options:
– Natural Gas models add suffix “N” – Propane models add suffix “P”
– High/Low fire add suffix “M” – Full Modulation add suffix “MOD”
PRESSURE DROP THROUGH HEAT EXCHANGER | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Model | Input | Output | 10°F | 20°F | 30°F | 40°F | 50°F | |||||||
btu | kW | btu | kW | GPM | FT.HD | GPM | FT.HD | GPM | FT.HD | GPM | FT.HD | GPM | FT.HD | |
AAA-480 | 480 | 141 | 394 | 115 | 82 | 12.5 | 41 | 3.2 | 27 | 1.4 | 20 | 0.8 | 16 | 0.5 |
AAA-600 | 600 | 176 | 510 | 149 | 102 | 12.7 | 51 | 3.2 | 34 | 1.5 | 26 | 0.5 | 20 | 0.6 |
AAA-720 | 720 | 211 | 612 | 179 | 122 | 13.4 | 61 | 3.4 | 41 | 1.5 | 31 | 0.7 | 24 | 0.6 |
AAA-840 | 840 | 246 | 714 | 209 | 143 | 12.1 | 71 | 3.1 | 48 | 1.4 | 36 | 0.6 | 29 | 0.5 |
AAA-960 | 960 | 281 | 816 | 239 | 163 | 13.6 | 82 | 3.4 | 54 | 1.5 | 41 | 0.7 | 33 | 0.6 |
AAA-1080 | 1080 | 317 | 918 | 269 | 184 | 13.7 | 92 | 3.9 | 61 | 1.6 | 46 | 0.7 | 37 | 0.6 |
AAA-1200 | 1200 | 352 | 1020 | 299 | 204 | 14 | 102 | 3.5 | 68 | 1.6 | 51 | 0.7 | 41 | 0.6 |
AAA-1320 | 1320 | 387 | 1122 | 329 | - | - | 112 | 3.5 | 75 | 1.5 | 56 | 0.8 | 45 | 0.6 |
AAA-1440 | 1440 | 422 | 1224 | 359 | - | - | 122 | 3.4 | 82 | 1.5 | 61 | 0.7 | 49 | 0.6 |
AAA-1560 | 1560 | 457 | 1326 | 389 | - | - | 133 | 2.9 | 88 | 1.3 | 66 | 0.6 | 53 | 0.5 |
AAA-1680 | 1680 | 492 | 1428 | 419 | - | - | 143 | 3.3 | 95 | 1.5 | 71 | 0.7 | 57 | 0.6 |
AAA-1800 | 1800 | 528 | 1530 | 448 | - | - | 153 | 3.4 | 102 | 1.5 | 77 | 0.8 | 61 | 0.6 |
AAA-1920 | 1920 | 563 | 1632 | 478 | - | - | 163 | 3.3 | 109 | 1.5 | 82 | 0.7 | 65 | 0.6 |
AAA-2040 | 2040 | 598 | 1734 | 508 | - | - | 173 | 3.3 | 116 | 1.5 | 87 | 0.6 | 69 | 0.6 |
AAA-2160 | 2160 | 633 | 1836 | 538 | - | - | 184 | 3.5 | 122 | 1.7 | 92 | 0.7 | 73 | 0.6 |
AAA-2280 | 2280 | 669 | 1938 | 568 | - | - | 194 | 4.5 | 129 | 2 | 97 | 1 | 78 | 0.7 |
AAA-2400 | 2400 | 703 | 2040 | 598 | - | - | 204 | 4.3 | 136 | 1.9 | 102 | 1 | 82 | 0.7 |
AAA-2495 | 2495 | 731 | 2121 | 622 | - | - | - | - | 141 | 1.9 | 106 | 0.8 | 85 | 0.7 |
AAA-2640 | 2640 | 774 | 2244 | 658 | - | - | - | - | 150 | 1.9 | 112 | 0.9 | 90 | 0.7 |
AAA-2760 | 2760 | 809 | 2346 | 688 | - | - | - | - | 156 | 1.8 | 117 | 0.9 | 94 | 0.7 |
AAA-2880 | 2880 | 845 | 2448 | 717 | - | - | - | - | 163 | 1.8 | 122 | 0.9 | 98 | 0.7 |
AAA-3000 | 3000 | 880 | 2550 | 747 | - | - | - | - | 170 | 1.8 | 128 | 1.0 | 102 | 0.7 |
Features
STAINLESS STEEL ATMOSPHERIC BURNERS – High grade, heat resistant stainless steel burners ensure years of trouble free service, exceptional performance and improved fuel efficiency with virtually no combustion noise.
DOUBLE PASS STEEL HEAT EXCHANGER – A unique double pass fin-tube heat exchanger offers increased heat transfer by incorporating spiral-welded fins. Steel headers and risers complete the double pass design and contribute to a sturdy, light weight heat exchanger that resists thermal shock. Large 2”OD ASME boiler tube waterways resist plugging and minimize pressure drop, reducing circulator capacity requirements. The heat exchanger requires no field assembly and has no gaskets or push nipples. No other heat exchanger offers such strength, rigidity, low cost, and efficiency.
SYSTEMS INTEGRATION – A 2-stage BC-1 controller is included with all boiler sizes. Optional direct digital control contacts and outdoor sensors are available.
RAPID RESPONSE – The AAA Series design ensures rapid response to calls for heat which is especially important when using indirect hot water heaters and tankless coils.
QUALITY CONSTRUCTION – AAA Series boilers are constructed to ASME section IV standards with a maximum working pressure of 160 psi (1100 kpa) and a maximum operating temperature of 240°F (115°C). Each is tested to 240 psi and certified by a third party inspector.
EASE OF INSTALLATION AND OPERATION – AAA boilers are the smart choice for swift, user friendly installation and easy, convenient maintenance. Direct digital control terminal contacts are available for integration into most modern building management systems. The AAA Series boiler’s modular design allows for easy dismantling and reassembly to transport through narrow doorways and passages.
STANDARD EQUIPMENT: Intermittent Electronic Pilot Ignition • Two Stage Gas Valve • Redundant Gas Valve • BC-1 Temperature Controller • Temperature/Pressure Gauge • On/Off Switch with Indicator Light • Operating and High Limit Aquastats • ASME 30 PSI Pressure Relief Valve • 24 Volt, 56 VA Transformer and Fuse • Drafthood • Main and Pilot Gas Pressure Regulators • High Gas Pressure Switch on Models Above 2,500 MBH Input
OPTIONAL EQUIPMENT: Low Water Cut Off • Flow Switch (Automatic or Manual Reset) • ASME Higher Pressure Relief Valves • CSD-1 Controls • Fully Modulating Gas Valve (BC-1 Controller Not Supplied With This Option) • Auto/Manual Switch • Flame Failure Alarm Feature • Direct Digital Control Terminal Contacts • Combination Seismic Restraint/Lifting Lugs • Higher Pressure ASME Relief Valves • High/Low Gas Pressure Switches (Automatic or Manual Reset) • Manual Reset for High Limit Aquastat • Propane • ASME “H” Stamped (Standard for US and Input Rates Greater or Equal to 1800 MBH)
RELIABILITY – Super Hot AAA boilers are constructed from the highest quality materials and built to exacting ASME standards. Allied Technologies is authorized by ASME to use the H stamp for heating boilers and is audited by their inspectors.
WARRANTY – The product comes with a ten year heat exchanger warranty and a one year parts and controls warranty. See warranty document for details.
ENVIRONMENT – Allied Technologies uses an environmentally friendly heat exchanger that is designed for longevity and 85% efficiency. Most components are recyclable after their long, trouble free life.
Service Bulletins
AAA-600 Draft Hood Size Change
This change affects the following models in both natural gas and propane.
AAA SERIES: AAA-600-N, AAA-600-P
This notice is to inform that models AAA-600 manufactured after June 11, 2016 will be provided with a 10 inch diameter draft hood.
This change was due to customer requests and, in cases of replacement of AAE-600 boilers, should make the AAA-600 boiler match with the previously installed venting system.
If you have any questions regarding this bulletin, please do not hesitate to contact Tony Woo at tony@alliedboilers.com or 604-929-1214.
AAA Commercial Boiler Unveiling
The brand new AAA Commercial Boiler has been officially unveiled and is ready for shipping.
The AAA is built on the legendary A Series platform that is known for its durability, longevity, and cost effectiveness. The AAA has a combustion efficiency of 85% and large 2″ waterways to prevent plugging and allow for large flow rates.
Warranty Cards
Remember that warranties are only valid if a warranty card is filled out and returned to Allied Technologies by the home owner. Online registration is available at our Product Registration Section of the website.