The SUPER HOT CX Heat Exchanger utilizes an all steel tank with an inner copper finned coil to provide system isolation and indirectly heat water.
– Ideal for isolating systems with non-oxygen barrier tubing or Poly-B to prevent corrosion in the primary loop
– Heats water indirectly and instantaneously when used with a boiler or alternative heat source
– High efficiency copper finned coil
– Wide diameter waterways resist “plugging up” when compared to typical flat plate heat exchangers
– Available in sizes ranging from 20,000 to 120,000 Btu/h
SPECIFICATIONS | |||||||||
---|---|---|---|---|---|---|---|---|---|
MODEL | DESIGN FLOW RATES (US GPM) | OUTPUT (BTU/hr) | CONNECTIONS (SHELL = FEMALE NPT, COIL = PLAIN END COPPER) | DIMENSIONS (INCHES) | SHIPPING WEIGHT (LB) |
||||
SHELL | COIL | A SHELL INLET | B SHELL OUTLET | C COIL INLET | D COIL OUTLET | E | |||
CX-20 | 2 | 2 | 20,000 | 1" | 1" | 1" | 1" | 5 3/4 | 8 |
CX-40 | 4 | 4 | 40,000 | 1" | 1" | 1" | 1" | 9 | 12 |
CX-60 | 6 | 6 | 60,000 | 1" | 1" | 1" | 1" | 12 1/4 | 15 |
CX-80 | 8 | 8 | 80,000 | 1" | 1" | 1" | 1" | 15 1/2 | 18 |
CX-100 | 10 | 10 | 100,000 | 1" | 1" | 1" | 1" | 18 3/4 | 21 |
CX-120 | 12 | 12 | 120,000 | 1" | 1" | 1" | 1" | 22 | 24 |
EFFICIENT & ECONOMICAL
The SUPER HOT CX heat exchanger is constructed from high efficiency finned copper tubing and geometrically designed to maximize heat transfer from the primary loop. Ambient temperature standby losses are virtually eliminated because there is no stack, flue or storage tank. The tankless coil saves energy by only heating the amount of water which will be used immediately.
SYSTEM ISOLATION
Ideal for isolating systems with non-oxygen barrier tubing or Poly-B to prevent corrosion in the primary loop. Radiant floor water inside the copper finned coil is heated by boiler water flowing through the steel shell. The primary boiler loop is isolated and protected from the corrosive water in the secondary loop which flows through the copper coil.
LONG-LASTING
Long-life copper tubing prevents corrosion problems associated with oxygenated water and open systems, while wide diameter waterways resist “plugging up” and ensures years of maintenance free heating.
EASY INSTALLATION
The compact design saves space and makes handling a breeze. Simple piping connections allow for quick and easy installation, saving you both time and money.
3 YEAR WARRANTY PROTECTION
SUPER HOT CX series heat exchangers are protected for 3 years against defective parts and fabrication, effective from the date of purchase, when used under normal operating conditions. See printed warranty for details.
Literature
No files found.
Service Bulletins
Warranty Cards
Remember that warranties are only valid if a warranty card is filled out and returned to Allied Technologies by the home owner. Online registration is available at our Product Registration Section of the website.